Product introduction This product refers to the People's Republic of Chinafire pumpAccording to the provisions of the standard GB6245-2006 "Fire Pump Performance Requirements and Test Methods", combined with the company's many years of production practical experience, it is designed with reference to modern excellent water conservancy models. It is specially used for the heart pump of the fire protection system. The product performance reaches the same level as domestic similar products. advanced level. The product passed the type test of the National Fire Equipment Quality Supervision and Inspection Center, and all performance indicators met the standard requirements. It was awarded the "Fire Protection Product Certification Certificate" issued by the Fire Protection Product Conformity Assessment Center of the Ministry of Emergency Management.
? ?
Parameter description

Flow range of conveyed liquid:1~5/s

Lift range:30~150m

Supporting power range:0.75~18.5

Rated speed:2900r/min

Material:Tank and pipeline carbon steel, ball sleeve pump body, stainless steel impeller, stainless steel shaft

? ?
working conditions

The equipment canfire water supplyThe most unfavorable point of the pipeline system always maintains fire pressure, and uses the 30-second fire water volume always stored in the pneumatic water tank to ensurefire pumpFire sprinkler water before operation;

This equipment uses the operating pressure set by the pneumatic water tank to control the operating conditions of the water pump to achieve the function of boosting and stabilizing pressure;

●P1 (MPa) The most unfavorable point always maintains the pressure required for fire protection:

●P2 (MPa) fire pump starting pressure;

●PS1 (MPa) stabilizes the pump starting pressure;

●PS2 (MPa) stabilizes the pump stop pressure.

Inquiry
view detail
XBD-L single-stage fire pump booster and voltage stabilizing supporting solutionXBD-L single-stage fire pump booster and voltage stabilizing supporting solution
01

XBD-L single-stage fire pump booster and voltage stabilizing supporting solution

2024-09-10
Product introduction This product refers to the People's Republic of Chinafire pumpStandard GB6245-2006《fire pump"Performance Requirements and Test Methods", combined with the company's many years of practical production experience and designed with reference to modern excellent water conservancy models, specially used for fire protection systemscentrifugal pump, product performance has reached the advanced level of similar domestic products. The product passed the type test of the National Fire Equipment Quality Supervision and Inspection Center, and all performance indicators met the standard requirements. It was awarded the "Fire Protection Product Certification Certificate" issued by the Fire Protection Product Conformity Assessment Center of the Ministry of Emergency Management.
? ?
Parameter description

Flow range of conveyed liquid:1~5/s

Lift range:30~150m

Supporting power range:0.75~18.5

Rated speed:2900r/min

Material:Tank and pipeline carbon steel, ball sleeve pump body, stainless steel impeller, stainless steel shaft

? ?
working conditions

The equipment canfire water supplyThe most unfavorable point of the pipeline system always maintains fire pressure, and uses the 30-second fire water volume always stored in the pneumatic water tank to ensurefire pumpbefore runningfire sprinkleruse water;

This equipment uses the operating pressure set by the pneumatic water tank to controlwater pumpoperating conditions, reachingBoost and stabilize voltagefunction;

●P1 (MPa) The most unfavorable point always maintains the pressure required for fire protection:

●P2(MPa)fire pumpPump starting pressure;

●PS1(MPa)Stabilizer pumpPump starting pressure;

●PS2(MPa)Stabilizer pumpStop pump pressure.

Inquiry
view detail
XBD-L-CDL main pump + multi-stage voltage stabilizing pump skid-mounted integrated pump unitXBD-L-CDL main pump + multi-stage voltage stabilizing pump skid-mounted integrated pump unit
01

XBD-L-CDL main pump + multi-stage voltage stabilizing pump skid-mounted integrated pump unit

2024-09-10
Product introduction This product refers to the People's Republic of Chinafire pumpStandard GB6245-2006《fire pump"Performance Requirements and Test Methods", combined with the company's many years of practical production experience and designed with reference to modern excellent water conservancy models, it is specially used for heart pumps in fire protection systems. The product performance has reached the advanced level of similar domestic products. The product passed the type test of the National Fire Equipment Quality Supervision and Inspection Center, and all performance indicators met the standard requirements. It was awarded the "Fire Protection Product Certification Certificate" issued by the Fire Protection Product Conformity Assessment Center of the Ministry of Emergency Management.
? ?
Parameter description

Flow range of conveyed liquid:1~5/s

Lift range:30~150m

Supporting power range:0.75~18.5

Rated speed:2900r/min

Material:Tank and pipeline carbon steel, ball sleeve pump body, stainless steel impeller, stainless steel shaft

? ?
working conditions

The equipment canfire water supplyThe most unfavorable point of the pipeline system always maintains fire pressure, and uses the 30-second fire water volume always stored in the pneumatic water tank to ensurefire pumpbefore runningfire sprinkleruse water;

This equipment uses the operating pressure set by the pneumatic water tank to controlwater pumpoperating conditions, reachingBoost and stabilize voltagefunction;

●P1 (MPa) The most unfavorable point always maintains the pressure required for fire protection:

●P2(MPa)fire pumpPump starting pressure;

●PS1(MPa)Stabilizer pumpPump starting pressure;

●PS2(MPa)Stabilizer pumpStop pump pressure.

Inquiry
view detail
XBC electric + backup diesel engine dual power skid-mounted fire pump setXBC electric + backup diesel engine dual power skid-mounted fire pump set
01

XBC electric + backup diesel engine dual power skid-mounted fire pump set

2024-09-10
Product introduction

Control mode:Manual/automatic, remote control functions support manual control, automatic control, and remote controlwater pumpThe start, stop and control modes can be switched;

Time setting:The control time of the diesel engine can be set, including: start delay time, preheating or pre-tuning time, start cut-off time, start-cut speed, rapid running time, speed-up process time, cooling down time;

Alarm shutdown:Automatic alarm and shutdown items: no speed signal overspeed, low speed, low oil pressure, high cooling temperature, start failure, shutdown failure, oil pressure sensor open circuit/short circuit, water temperature sensor open circuit/short circuit, speed sensor open circuit/short circuitwater pumpWater pressure is too low, etc.;

Early warning items:Pre-alarm items: over speed, low speed, low oil, high cooling temperature, low temperature, low fuel level, low battery voltage, high battery voltage, speed signal is not calibrated andpumpWater pressure is too low, etc.

Status display:Diesel engine operating status display: According to the current actual situation of the system, the current status of the equipment is displayed: waiting, engine, fuel supply, start, start delay, rapid delay, normal operation, clean shutdown, emergency shutdown;

Parameter display:Diesel engine parameter measurement display: During system operation, the current relevant parameter values ??are displayed: rotation speed, running time fuel volume, battery voltage, cooling temperature, and oil pressure.

? ?
Parameter description

Flow range of conveyed liquid:5~500L/s

Lift range:15~160m

Supporting power range:28~1150kw

Rated speed:1450~2900r/min

? ?
working conditions

The medium weight does not exceed 1240kg/m';
The ambient temperature is

The self-priming height cannot exceed 4.5~5.5 meters, and the length of the suction pipe is

The rotation speed is generally 1450r/min~3000r/min.

? ?
Application areas

XBC-QYS typeDiesel engine fire pump unitIt is in accordance with the standard requirements and test methods. The B6245-2006《fire pumpThe performance series products have a wide range of lift and flow, which can fully meet the requirements of various occasions such as warehouse factories, liquefied gas stations, textile and other terminals, airports, petrochemical, electrical and mining enterprises.fire water supply. The advantage is that the building is protectedpumpUnable to start, after the diesel engine power system suddenly loses powerElectric fire pumpAutomatically start investmentemergency water supply.